3-1/2 Ton 43,250 BTUH 208/230 Volt 3-Phase Air Conditioning ROTOLOCK Compressor (American Standard,

3-1/2 Ton 43,250 BTUH 208/230 Volt 3-Phase Air Conditioning ROTOLOCK Compressor (American Standard,
Code: COMP40JH3
Price: $1,157.64
Quantity in Basket: None
Quantity:
3-1/2 Ton 43,250 BTUH 208/230 Volt 3-Phase Air Conditioning ROTOLOCK Compressor (American Standard, Maneurop, Trane)

3-1/2 208/230 TON UNIVERSAL 3 PHASE SWEAT CONNECTION COMPRESSOR LISED @ THE BOTTOM OF THIS PAGE

Description
Replaces many Trane, American Standard OEM compressors.
Designed with large internal open area to reduce liquid hammering.
Entirely suction cooled, no external cooling required.
Built for long lasting, transient tolerant performance.
Tripod mount on 1, 2 cylinder models. 9.7" square mount 4
cylinder MTZ100 and larger. Rotolock connections; sweat spuds
provided. Run capacitor required for single phase models, not provided.
• Charged with mineral oil
• Capacity rated R22, +45°F SST

Product Specifications:
Horsepower: 3 1/2
Voltage: 208-230/3/60
Rated Load Amps: 24.3
Oil: Mineral
Mount (In.): Tripod
Height (In.): 12.6
Shipping Weight (Lbs.): 60
Connection Suction (In.): 1 1/4RL-5/8
Connection Discharge (In.): 1RL-1/2
Connection Type: Rotolock connections; sweat spuds provided.
Refrigerant: R22
Capacity (BTUH): 43,250
Engineered Items: Yes
LTL Only: Yes
Oil_short: MIN

Replaces Part Numbers:

COM-2799 COM2799 COMO2799 COM02799 COM-3159 COM3159 COMO3159 COM03159 WW77X905 P031-4251 P0314251 911503 46F9801 19F5401 68J6201 CL31Y15 CT40JH3 WW77X252 WW77X706 COM-2812 COM2812 COMO2812 COM02812 COM-3541 COM3541 COMO3541 COM03541 WW77X206 COM-2918 COM2918 COMO2918 COM02918 COM-2542 COM2542 COMO2542 COM02542 WW77X413 WW77X281 WW77X490 COM-3850 COM3850 COMO3850 COM03850 COM-3397 COM3397 COMO3397 COM03397 COM02201 COM2201 CT44HJ3A CARMT40JH3

Used in Air Conditioning Models:

PWY042CAVA PWY042CAVA09 PWY042CAVA15 PWY042CAVA18 PWY048BAVAA PWY048BAVAA10 PWY048BAVAA15 PWY048BAVAA20 PWYB042C CHA15-460-1 CHA154601 CHA15-460-3 CHA154603 CHP10-410-3 CHP104103 CHP15-460-1 CHP154601 CHP15-460-3 CHP154603 CHP9-410-5 CHP94105 HP19-510-1 HP195101 HP19-510-3 HP195103 HS18-460-3 HS184603 HS18-460-4 HS184604 CHA9-410-5 CHA94105 GCS10-460-75-1 GCS10460751 GCS10-460-75-3 GCS10460753 GCS10X-460-75-1 GCS10X460751 GCS10X460753 MCHA9-410-5 MCHA94105 HP29-042-1 HP290421 HP29-460-1 HP294601 HP29-460-2 HP294602 HS29-042-9 HS290429 HS29-460-1 HS294601 HS29-460-2 HS294602 LCA042S-1 LCA042S1 LGA042S-78-1 LGA042S781 BGTA836R3D BGTA836R3DG BGWC036A3E TA036M3A BGTA836R3A BGTA836R3G BGWA836R3A BGWA936H3A BGWC036A3D BGWC036A6D BGYC036A3A08 BGYC036A3B08 BGYC036A3B12 BGYC036A4A BC0036B309A0 BC0042A308A0 BC0042D312A BTA030B600A0 BTA030B600A1 BTA030B600B0 BTA036B300A0 BTA036B300A1 BTA036B300B0 BTA036C300A0 BTA036C300B0 BTA036C300B1 BTC030B600B0 BTC036B300C0 BTC036E300A0 BTC036E300B0 BTR030A600A0 BTR036A300A0 BTR036A300A1 BTR036A300A3 BWC036E300A0 BWC036E300B0 BWC036E300B1 BWR730A600A0 BWR730A600B0 BYC036B312C0 BYC036B312EO BYC036B312E1 BYC036B312F0 BYC036B312FR BWC042C300D1

* Installation

When installing your new compressor, you may need additional copper fittings and tubing in some older model compressors when retro-fitting to new upgraded compressor models.

* Compressor Performance:

BtuH Ratings are based 0n 45 F evaporating temperature 130 F, condensing temperature, 65 F return gas temperature and 95 F, liquid temperature.

Replaces Compressor Part Numbers: CAR

* IMPORTANT!!! - PLEASE NOTE: IDENTIFYING COMPRESSOR FAILURES

Most compressors fail due to system malfunctions, which must be corrected to prevent repeat failures. After a compressor fails, field examination of the failed compressor often will reveal symptoms of system problems. Proper corrections will help eliminate future failures.

* SINGLE PHASE BURN

Two phases of a three-phase motor overheated or burned as a result of the contactor opening only one of its contacts.

Correction:

(1) Replace contactors with properly sized contactors.
(2) Check for proper motor protection.

* HALF WINDING SINGLE PHASE BURN

In a two contactor application, two phases of one half of a three phase motor overheated or burned as a result of one contactor opening only one contact.

Correction:

(1) Replace contactors with properly sized contactors.

* HALF WINDING BURN

Half of all phases on a two contactor three phase motor are overheated or burned due to only one contactor opening.

Correction:

(1) Replace contactors with properly sized contactors.
(2) Check for feed back circuit holding one contactor closed.

* PRIMARY SINGLE PHASE BURN

Only one phase of a three phase motor is overheated or burned as the result of opening one phase on the primary side a delta to wye transformer.

Correction:

(1) Check primary side of a delta to wye main power transformer.

* START WINDING BURN

The start winding only of a single-phase motor is uniformly overheated or burned.

Correction:

(1) Check for proper wiring of compressor.
(2) Check starting capacitor and/or starting relay.
(3) Correct compressor overloading.

* SPOT BURN

A localized burn within a winding, between windings, or from windings to ground. If not the result of mechanical problems, check for spikes or surges of high current flow.

* SHORTED TERMINALS

A break down of the insulation between terminals and compressor body generally the result of over torque terminals.